V.A.D. s.r.o. V.A.D. s.r.o.
Inicio
Nosotros Historia
Legal
Términos y condiciones Política de privacidad
Contacto
Plataforma IIoT Actualizado Dispositivos de telemetría Planes de suscripción
Soluciones Blog Documentación
  • en English
  • de Deutsch
  • sk Slovenčina
  • cs Čeština
  • it Italiano
  • es Español ✓
  • ru Русский
  • uk Українська
  • uz Oʻzbekcha
Iniciar sesión
V.A.D. s.r.o. V.A.D. s.r.o.

Navegación

  • Inicio
  • Empresa
    • Nosotros
    • Historia
    • Legal
      • Términos y condiciones
      • Política de privacidad
    • Contacto
  • Productos
    • Plataforma IIoT Actualizado
    • Dispositivos de telemetría
    • Planes de suscripción
  • Soluciones
  • Blog
  • Documentación
Iniciar sesión
ES
  • en English
  • de Deutsch
  • sk Slovenčina
  • cs Čeština
  • it Italiano
  • es Español ✓
  • ru Русский
  • uk Українська
  • uz Oʻzbekcha
Volver a dispositivos
VADTel ValveLink valve-control unit — front view VADTel ValveLink valve-control unit — front view

Valve-control unit

VADTel ValveLink

Remote valve control unit for utility shutoff, enabling fast remote response from the VAD IIoT Platform.

  • Remote valve control over GPRS / NB-IoT cellular
  • Four switched outputs for compressor and pneumatic manifold
  • Isolated RS-485 acquisition from meters, correctors & calculators
  • Cabinet tamper and actuator stem-position supervision
Conformity

EU Declaration of Conformity

Lifecycle

WEEE disposal & traceability

Application class

Non-Ex cabinet installation

Solicitar presupuesto Especificaciones técnicas
  • Remote valve control

    Drive the compressor and pneumatic manifold and issue open/close commands from the VAD IIoT Platform over cellular — response in minutes rather than hours.

  • Metering-node integration

    Polls compatible RS-485 meters, correctors and calculators for live values, archives, configuration data and events — one cabinet node for telemetry and control.

  • Cabinet supervision

    Monitors the cabinet tamper contact and actuator stem position, with an audit-grade log of every valve state change reported to the platform.

  • Field-ready form factor

    DIN-rail enclosure, 12–24 V DC supply and −40…+60 °C operation, engineered for unattended utility cabinets in gas, water and heat nodes.

  • Diagnostics & service history

    Tracks valve-drive health, limit-switch status and response time, with full maintenance and service-history records on the platform.

VADTel ValveLink is the cabinet-level node of the VADTel telemetry stack. It combines cellular communication, isolated RS-485 acquisition from compatible external metering devices, cabinet tamper supervision, actuator-position interfacing and dedicated outputs for pneumatic-manifold and compressor control — all in a single DIN-rail device sized for 12–24 V DC utility cabinets.

The controller acts as the link between the local valve assembly, the metering devices and the supervisory backend. It polls compatible meters over RS-485, supervises cabinet-level status, drives the valve equipment according to project logic, and reports telemetry through GPRS / NB-IoT communication.

Where it fits

  • Gas — metering nodes with remote shutoff, gas volume correctors and cabinet telemetry.
  • Water — distribution chambers and metering cabinets with automated valves and compatible RS-485 metering.
  • Heat — heat calculators, valve stations and district-heating substations with cabinet-level telemetry.

Control & telemetry workflow

  1. Poll meters — read current values, archives and events from compatible RS-485 devices.
  2. Monitor local state — supervise the cabinet tamper input, actuator stem position and cabinet-level status.
  3. Control valve equipment — drive the compressor and pneumatic manifold through the four switched outputs according to project logic.
  4. Report telemetry — send telemetry and event data to the supervisory system over cellular communication.

Cabinet-level architecture

A typical installation pairs ValveLink with a 12/24 V supply or battery-backed cabinet power, a GSM antenna, a cabinet door switch, a compressor and pneumatic manifold, an actuator-position board and a pneumatic actuator on the valve stem. On the metering side it connects to compatible resource meters, gas volume correctors, water meters, heat calculators and other RS-485 devices. Pressure sensing and the final electrical implementation depend on the project variant and wiring documentation.

Managed from the VAD IIoT Platform

The cloud-based IIoT Ecosystem turns the cabinet node into a fully supervised asset:

  • Remote valve control — open / close — through cellular communication.
  • Real-time device status monitoring and communication-session tracking.
  • A management log with a full audit trail of valve state changes.
  • Device diagnostics: valve-drive health, limit-switch status and response time.
  • Service history with maintenance records, job types and executor tracking.

Application limit

VADTel ValveLink is a cabinet-level controller and telemetry unit. It is not a stand-alone gas safety shutoff device; final compliance of the complete installation remains with the system integrator. The standard product version is intended for non-Ex cabinet installation.

Combined with VADTel Sens for pressure monitoring and an IIoTU3 or AIIoTU8 module for connectivity, ValveLink forms a complete remote-shutoff loop — a key building block for utilities working under the EU Methane Regulation and similar safety frameworks.

Full documentation — product passport, technical specifications, EU declaration of conformity and installation instructions — is available on the IoT documentation portal.

Power & safety
Mounting DIN rail, cabinet installation
Supply voltage 12–24 V DC
Max power consumption 15 W
Internal circuits SELV < 30 V DC
Overvoltage category OVC II
Pollution degree 2
Operating temperature −40 °C to +60 °C
Control outputs
OUT1–OUT3 3 outputs, 12/24 V DC, 5 A max each
OUT4 1 output, 12/24 V DC, 10 A max
Inductive loads External suppression required
Inputs & local interfaces
Tamper input (IN-TAMPER) Dry contact, 1 input
Position sense (POS-SENSE) 3-wire, 3.0–4.2 V DC
I²C 3.3 V logic
Communications
Cellular GPRS / NB-IoT (LTE Cat-NB1 / NB2)
RS-485 1 isolated port, A/B
RS-485 signal level 1.5–5 V differential
Metering scope Compatible external meters / correctors / calculators
Telemetry & metering
Metering-node functions Live values, archives, configuration exchange, event and status logs
Compatible field devices Gas volume correctors, water meters, heat calculators, cabinet door switch, compressor, pneumatic manifold, actuator position board
Product & compliance
Model VADTel-IIoTu-ValveLink
Standard part number VAD-IIOTU-VLK-01
Form factor DIN-rail controller
Conformity CE marking, EU Declaration of Conformity
Application class Non-Ex cabinet installation

Documentación completa del producto

Abra el pasaporte del producto, las especificaciones técnicas, la declaración de conformidad UE, la declaración RoHS y los informes de prueba en nuestro portal de documentación.

Abrir el portal de documentación

¿Necesita este dispositivo para su proyecto?

Contáctenos para obtener especificaciones técnicas, precios y condiciones para pedidos por volumen.

Solicitar presupuesto

Escribe para buscar...

↑↓ navegar ↵ abrir ⌘↵ en nueva pestaña
Esc Cerrar búsqueda

Cookies

Usamos cookies para analizar el tráfico y el rendimiento del sitio; tu privacidad es importante para nosotros.

Preferencias de cookies

Usamos cookies para ofrecer una mejor experiencia de navegación, analizar el tráfico del sitio y proporcionar contenido y anuncios personalizados.

V.A.D. s.r.o. V.A.D. s.r.o.

Soluciones de telemetría, fabricación de dispositivos de telemetría y software inteligente para la contabilización de energía.

Enlaces Rápidos

Inicio Productos Contactos Sobre nosotros Historia

Recursos

Documentación Plataforma IIoT Suscripción Soluciones
Nuevo
Blog

Contacto

inbox@vadsro.eu
+421 910 411 379
Konventna 6, 81103 Bratislava, Eslovaquia

© 2026 V.A.D. s.r.o.. Todos los derechos reservados.

Condiciones Privacidad Mapa del sitio