V.A.D. s.r.o. V.A.D. s.r.o.
Bosh sahifa
Biz haqimizda Tarix
Huquqiy ma'lumotlar
Foydalanish shartlari Maxfiylik siyosati
Aloqa
IIoT platformasi Yangilangan Telemetriya qurilmalari Obuna rejalari
Yechimlar Blog Hujjatlar
  • en English
  • de Deutsch
  • sk Slovenčina
  • cs Čeština
  • it Italiano
  • es Español
  • ru Русский
  • uk Українська
  • uz Oʻzbekcha ✓
Kirish
V.A.D. s.r.o. V.A.D. s.r.o.

Navigatsiya

  • Bosh sahifa
  • Kompaniya
    • Biz haqimizda
    • Tarix
    • Huquqiy ma'lumotlar
      • Foydalanish shartlari
      • Maxfiylik siyosati
    • Aloqa
  • Mahsulotlar
    • IIoT platformasi Yangilangan
    • Telemetriya qurilmalari
    • Obuna rejalari
  • Yechimlar
  • Blog
  • Hujjatlar
Kirish
UZ
  • en English
  • de Deutsch
  • sk Slovenčina
  • cs Čeština
  • it Italiano
  • es Español
  • ru Русский
  • uk Українська
  • uz Oʻzbekcha ✓
Qurilmalarga qaytish
VADTel ValveLink valve-control unit — front viewVADTel ValveLink valve-control unit — front view

Valve-control unit

VADTel ValveLink

Remote valve control unit for utility shutoff, enabling fast remote response from the VAD IIoT Platform.

  • Remote valve control over GPRS / NB-IoT cellular
  • Four switched outputs for compressor and pneumatic manifold
  • Isolated RS-485 acquisition from meters, correctors & calculators
  • Cabinet tamper and actuator stem-position supervision
Conformity

EU Declaration of Conformity

Lifecycle

WEEE disposal & traceability

Application class

Non-Ex cabinet installation

Taklif so‘rash Texnik xususiyatlar
  • Remote valve control

    Drive the compressor and pneumatic manifold and issue open/close commands from the VAD IIoT Platform over cellular — response in minutes rather than hours.

  • Metering-node integration

    Polls compatible RS-485 meters, correctors and calculators for live values, archives, configuration data and events — one cabinet node for telemetry and control.

  • Cabinet supervision

    Monitors the cabinet tamper contact and actuator stem position, with an audit-grade log of every valve state change reported to the platform.

  • Field-ready form factor

    DIN-rail enclosure, 12–24 V DC supply and −40…+60 °C operation, engineered for unattended utility cabinets in gas, water and heat nodes.

  • Diagnostics & service history

    Tracks valve-drive health, limit-switch status and response time, with full maintenance and service-history records on the platform.

VADTel ValveLink is the cabinet-level node of the VADTel telemetry stack. It combines cellular communication, isolated RS-485 acquisition from compatible external metering devices, cabinet tamper supervision, actuator-position interfacing and dedicated outputs for pneumatic-manifold and compressor control — all in a single DIN-rail device sized for 12–24 V DC utility cabinets.

The controller acts as the link between the local valve assembly, the metering devices and the supervisory backend. It polls compatible meters over RS-485, supervises cabinet-level status, drives the valve equipment according to project logic, and reports telemetry through GPRS / NB-IoT communication.

Where it fits

  • Gas — metering nodes with remote shutoff, gas volume correctors and cabinet telemetry.
  • Water — distribution chambers and metering cabinets with automated valves and compatible RS-485 metering.
  • Heat — heat calculators, valve stations and district-heating substations with cabinet-level telemetry.

Control & telemetry workflow

  1. Poll meters — read current values, archives and events from compatible RS-485 devices.
  2. Monitor local state — supervise the cabinet tamper input, actuator stem position and cabinet-level status.
  3. Control valve equipment — drive the compressor and pneumatic manifold through the four switched outputs according to project logic.
  4. Report telemetry — send telemetry and event data to the supervisory system over cellular communication.

Cabinet-level architecture

A typical installation pairs ValveLink with a 12/24 V supply or battery-backed cabinet power, a GSM antenna, a cabinet door switch, a compressor and pneumatic manifold, an actuator-position board and a pneumatic actuator on the valve stem. On the metering side it connects to compatible resource meters, gas volume correctors, water meters, heat calculators and other RS-485 devices. Pressure sensing and the final electrical implementation depend on the project variant and wiring documentation.

Managed from the VAD IIoT Platform

The cloud-based IIoT Ecosystem turns the cabinet node into a fully supervised asset:

  • Remote valve control — open / close — through cellular communication.
  • Real-time device status monitoring and communication-session tracking.
  • A management log with a full audit trail of valve state changes.
  • Device diagnostics: valve-drive health, limit-switch status and response time.
  • Service history with maintenance records, job types and executor tracking.

Application limit

VADTel ValveLink is a cabinet-level controller and telemetry unit. It is not a stand-alone gas safety shutoff device; final compliance of the complete installation remains with the system integrator. The standard product version is intended for non-Ex cabinet installation.

Combined with VADTel Sens for pressure monitoring and an IIoTU3 or AIIoTU8 module for connectivity, ValveLink forms a complete remote-shutoff loop — a key building block for utilities working under the EU Methane Regulation and similar safety frameworks.

Full documentation — product passport, technical specifications, EU declaration of conformity and installation instructions — is available on the IoT documentation portal.

Power & safety
MountingDIN rail, cabinet installation
Supply voltage12–24 V DC
Max power consumption15 W
Internal circuitsSELV < 30 V DC
Overvoltage categoryOVC II
Pollution degree2
Operating temperature−40 °C to +60 °C
Control outputs
OUT1–OUT33 outputs, 12/24 V DC, 5 A max each
OUT41 output, 12/24 V DC, 10 A max
Inductive loadsExternal suppression required
Inputs & local interfaces
Tamper input (IN-TAMPER)Dry contact, 1 input
Position sense (POS-SENSE)3-wire, 3.0–4.2 V DC
I²C3.3 V logic
Communications
CellularGPRS / NB-IoT (LTE Cat-NB1 / NB2)
RS-4851 isolated port, A/B
RS-485 signal level1.5–5 V differential
Metering scopeCompatible external meters / correctors / calculators
Telemetry & metering
Metering-node functionsLive values, archives, configuration exchange, event and status logs
Compatible field devicesGas volume correctors, water meters, heat calculators, cabinet door switch, compressor, pneumatic manifold, actuator position board
Product & compliance
ModelVADTel-IIoTu-ValveLink
Standard part numberVAD-IIOTU-VLK-01
Form factorDIN-rail controller
ConformityCE marking, EU Declaration of Conformity
Application classNon-Ex cabinet installation

Mahsulotning to‘liq hujjatlari

Mahsulot pasporti, texnik xususiyatlar, EI muvofiqlik deklaratsiyasi, RoHS deklaratsiyasi va sinov hisobotlarini bizning hujjatlar portalimizda oching.

Hujjatlar portalini ochish

Loyihangiz uchun ushbu qurilma kerakmi?

Texnik xususiyatlar, narxlar va katta hajmli buyurtmalar shartlari uchun biz bilan bog‘laning.

Taklif so‘rash

Qidirish uchun yozing...

↑↓ harakatlanish ↵ ochish ⌘↵ yangi yorliqda
Esc Qidiruvni yopish

Cookies

Biz sayt trafiki va ishlashini tahlil qilish uchun cookies fayllaridan foydalanamiz; maxfiyligingiz biz uchun muhim.

Cookies sozlamalari

Biz ko'rish tajribasini yaxshilash, sayt trafikini tahlil qilish va shaxsiylashtirilgan kontent hamda reklamalarni taqdim etish uchun cookies fayllaridan foydalanamiz.

V.A.D. s.r.o. V.A.D. s.r.o.

Telemetriya yechimlari, telemetriya qurilmalari ishlab chiqarish va energiya hisobga olish uchun aqlli dasturiy ta'minot.

Tezkor havolalar

Bosh sahifa Mahsulotlar Kontaktlar Biz haqimizda Tarix

Resurslar

Hujjatlar IIoT Platformasi Obuna Yechimlar
Yangi
Blog

Kontaktlar

inbox@vadsro.eu
+421 910 411 379
Konventna 6, 81103 Bratislava, Slovakiya

© 2026 V.A.D. s.r.o.. Barcha huquqlar himoyalangan.

Shartlar Maxfiylik Sayt xaritasi